您好,通达利官方网站欢迎您!

公司地图|官方微博|官方微信|联系通达利

深圳通达利企业顾问公司

迪士尼验厂

通达利企业顾问

专注验厂服务16年,业内优秀品牌

  • 轻松通过

    轻松通过

  • 实力公关

    实力公关

  • 您的信赖之选

    您的信赖之选

  • 13802559095 李浩

    18664351804梁小姐

沃尔玛验厂

联系我们

2016沃尔玛接受现场整改的24条。

文章来源:深圳通达利企业顾问公司人气:4421发表时间:2016-07-29

沃尔玛接受现场整改的24

2016年沃尔玛方面明确公布以下问题点可以接受工厂现场整改


▶   1. Walmart Standards:沃尔玛标准

Not posted;未张贴

Not posted in local language非本地语言张贴

▶   2. Spill Response Material / Secondary Containment (110%):二级防护措施

Not present;没有

Inappropriate不适宜

▶   3. None or insufficient/improper:没有或者不足/不适宜

MSDS;物料安全数据表

Hazardous signing;危险物品标志

Labeling / inventory.标签/

▶   4.Working areas:工作区域

Present safety hazard (Fall, Hole, Etc.)安全隐患(物品滑落,洞,等等)

▶   5.First Aid box supplies:急救

Not sufficient.不足

▶   6. Waste containers废物箱

Not identified;没有注明

Labeled by type and hazard按类别的危险级别分部标记

▶   7. Drainage system:排水系统

No clear layout布局不明显

▶   8. Machine Safety:机器安全

No posting of machine safety instructions in local language没有张贴用当地语言表示的机器安全指示

▶   9.Evacuation plan:紧急疏散计

Is not present;没有

Does not have "YOU ARE HERE" mark;没有 “你在这里“的标识

Does not match facility layout;不符合工厂实际布局

Is not in language spoken by majority of employees.不是大部分员工使用的语言

▶   10. The facility evacuation plan:紧急疏散计划

 Is not posted in legally required areas;未张贴在符合规定的区域

Is not posted in every production area;未张贴在每一个生产区域

Is not posted in high-concentration areas;张贴在人员密度高的区域

Is not posted near entrances to stairwells贴在出口或者楼梯口附近.未张

▶   11.Emergency exit routes:紧急出口路线

Are not marked with directional signs;没有指示标志做标记

Are not lit.不亮

▶   12.mergency Exits:紧急出口

Are not designated as emergency exits;未指明为紧急出口

Do not have illuminated EXITsigns;无带电的“出口”标记

Do not have an EXITsign in a language spoken by majority of employees.“出口”标记不是大部分员工使用的语言

▶   13.Facility emergency exit doors:工厂紧急出口门

Do not have a landing with at least 1 meter (3 feet) before beginning of first step.没有距离第一个阶梯1米(3英尺)的楼梯平台(缓冲带)

▶   14.Facility emergency fire alarms:工厂紧急火灾警报器

Have error indicators on the fire alarm control panel.消防警报器控制板上错误的指导

▶   15.Facility emergency fire alarms:警铃

Are not audible;听不到警铃

Do not have beacon or flashing lights in high-noise areas.噪音大的区域未安装信号灯和闪光式警铃

▶   16.Facility emergency fire alarms:警铃

Are not connected to a secondary power source.未连接备用电源

▶   17.Emergency exit lights:应急灯

Are not connected to a secondary power source.未连接备用电源

▶   18.Facility emergency exit doors:紧急出口门

Are not side-hinged doors;不是侧铰链门

Do not open in the direction of travel with a single motion;不能一个动作向逃生方向开启

Do not close automatically when leading to a staircase;当推开至楼梯时不能自动关闭

▶   19.Emergency assembly areas:工厂紧急集合区域

Are not designated on evacuation plan;未在疏散计划图上有指明

Are not located along each fire escape route.并非每个逃生路径均可前往

▶   20.Fire extinguishers:灭火器

Are not present on every floor of the facility;不能覆盖工厂的每一层

Are not present in every production area;不能覆盖工厂每个区域

Are not present in areas where there is storage of materials labeled as flammable. 不能覆盖储存易燃物品的区域

▶   21.Fire Extinguishers:灭火器

Are not mounted;未离地放置

Are mounted above 1.5 meters (5 feet) from ground to top of fire extinguisher.灭火器顶部距离大于1.5

▶   22.Fire Extinguishers:灭火器

Are overcharged;压力过大

Are undercharged.压力不足

▶   23.Materials labeled as hazardous, combustible, or flammable:危险物品、可燃或易燃物品

Are not stored in containers labeled as anti-static;未存放在标识了防静电的容器内

Are not grounded.未接地

▶   24.Electrical wiring:电线

Is damaged or exposed; 是损坏的或者暴露的

Is connected through extension cords通过延长线连接